Lifestyle questions and answers

Ask a question on any topic and get answers from real people on Yahoo! Canada Answers

  • A stumper for the HVAC technicians?

    Maintenance & Repairs - 6 hours ago

    Additional Details

    So I'm in an HVAC class. My lab was a unit change out. Everything was going smooth and easy, until I tried to raise the head pressure to 278 psig. The first time I got my head pressure up around 278 psig. While measuring my subcool(which was fluttering around 20 degrees) the high pressure switch cut out. After that It cut out at around 160psig. I bypassed the hi/lo pressure switches, because they kept tripping, and raised head pressure to 200 psig. Above that and the compressor cuts out while the condenser fan keeps blowing. I weighed in the charge of 5.8 lbs of R-22, like the label on the unit called for, if anything it is overcharged. I pulled a triple evac. It is not on me yet to troubleshoot this unit, but I hate failure. This one has two of my instructors suspecting different causes; bad compressor or undercharge. Any ideas? To raise the head pressure, we wrap the coils with plastic and limit airflow. I say it is overcharged because 5.8 lbs is a complete charge with 25' of lineset. This unit has approximately 19' of lineset. The evap coil was not replaced with the condenser. The TXV works fine, it maintains 10 degrees superheat. I think I got everything. The filter drier is just a standard issue. About the size of an orange. The sight glass has a few stray bubbles, which I have received mixed information on. A short time instructor said a proper charge should show no bubbles, another instructor said a proper charge would show some bubbles. The subcool number does show an undercharge...either a coolant loss or I had the scale set to kilos? I think it was a potential relay. All those little black boxes look the same, and I could not see the wiring diagram without removing it from the unit. discharge temp. was around 85-110, the higher number with higher pressure. hermetic, scroll, 208 volt, high temp, used residential unit. We have dozens of A/C's, I swapped out a 13 SEER unit for an antique 12 SEER Rheem. I don't remember the amp draw, but it did increase as pressure rose. This problem developed near the end of the day. So we didn't have time to start troubleshooting. School is closed till Monday, but I have been pondering this since last night. From the questions you have led me with, I tend to suspect the compressor. The compressor was extremely hot to the touch. I think it was a potential relay. I could not read the schematic on it. I admit I am a rookie with no practical field experience. evap pressure stays steady at 70 psig. The pressure rises to around 80 psig when head pressure is forced up to 200 psig.
  • need help with upholstery fabric?? advice?

    Decorating & Remodeling - 10 hours ago

    Additional Details

    I'm buying fabric for my couches and I wanted to know if a blend of wool and polyester would be a good fabric.. I want something that is colour durable, easy to clean and would last a long time.. OH and something that wont lint up when i put it in the wash.. if anyone knows of such fabric please let me know.. thanks in advance
  • Drywalling question(gaps and jagged sheetrock).?

    Do It Yourself (DIY) - 12 hours ago

    Additional Details

    I'm not sure if I make sense to you, this is hard to explain. Basically there is a hole or groove about a inch deep in the sheetrock where he failed to snap the board clean. The grove is located in the middle on the ending. Now when I tape over this I can sorta see that I'm taping over a hole in a wall. I feel like this is not the proper way to do it and it can easy be "punched" through later on. What can I do to fix this gap so I can tape over something solider and the paste?
  • How do I clean my UGG's?

    Cleaning & Laundry - 13 hours ago

    Additional Details

    I always wear them without socks because they are so warm and fluffy inside so Im thinking I should clean them, can they go in the washing machine and the dryer?
  • Can I let carpet deodorizer sit overnight?

    Cleaning & Laundry - 15 hours ago

    Additional Details

  • Are GE front load washing machines supposed to pause?

    Cleaning & Laundry - 15 hours ago

    Additional Details

    It pauses for about 3 sec about every minute during the washing.
  • framing metal studs and drywall?

    Decorating & Remodeling - 17 hours ago

    Additional Details

    someone knows who is hiring.i do framing metal stud,drywall,& T bar suspended ceiling and also i have my own laser for T bar ceiling i have more than 10 years experience i am available in east wenatche wash. thanks
  • What is the best time of the year to trim Burning Bush hedges?

    Garden & Landscape - 17 hours ago

    Additional Details

    I always thought you were supposed to trim them in springtime, but right now those little spindly branches with no leaves on them look pretty easy to trim to the height I want them at ......
  • How do I get these trip switches on again?

    Do It Yourself (DIY) - 17 hours ago

    Additional Details

    Hi. I was at work and, in a fit of utter stupidity, I went to the swtichboard and flicked some of the trip switches off. Now they won't switch back on again. I tried to switch them on and they just kept going back to off. Please help before anyone notices that nothing is working. Is there an easy way to get them back on again? I don't want to get the sack. I think I might just pretend it was a storm that did it. But I don't know if I can get away with it. Please help! I think the switches are right over into the off position already but I'll check. I think I have to call in the electricians and pay for them to fix it (in the middle of the night), because if the company can't function due to a strange lack of electricity then it will cause a lot of problems and then people will get angry and I will have to hide in the cupboards again. And I don't want to do that because it's very uncomfortable after the first few hours.
  • HELP QUICK :| before mom gets back LOL?

    Cleaning & Laundry - 18 hours ago

    Additional Details

    I brought Heart Shaped Handwarmers from iwoot.com and your meant to boil them for 20 minutes to reuse, i boiled them too long and almost burnt my kitchen down :( and now it stinks >.< how'd i get fumes out QUICK omg, thanks so much everyone who commented :P she found out, but i think she's calmed down a bit, fingers crossed :D omg, thanks so much everyone who commented :P she found out, but i think she's calmed down a bit, fingers crossed :D

Built-In vs. Freestanding Closets

Get organized using one (or both) of these storage solutions

Provided by Wish

Built-in closets are great for:

1. Utilizing every inch of your space.

2. Matching the closet with the décor and architecture of the room.

3. Creating as many recesses, hooks and accessory drawers as you need to keep things organized.

4. Increasing the value of your property.

5. Freeing up floor space. They’re great for condos or smaller apartments, too.

Free-standing closets or armoires are great for:

1. Renters – you take it with you when you move.

2. Saving space by storing different items (like clothes and shoes) together in one unit.

3. Any budget. You can splurge on a solid investment piece, or simply roll out an affordable garment rack. Tip: A rolling rack works especially well in lofts or industrial-style spaces.

4. Moving with the times. Extra shelves, rods, drawers and hooks can be easily added or removed to accommodate a changing lifestyle.

5. Storage solutions. Because it’s easily transportable, a free-standing unit can be repurposed to keep sports equipment under control in the garage, or to house office or gift-wrapping supplies indoors.

Not Yet Rated

0 Comments

LEAVE YOUR COMMENT
character(s) remaining

You must sign in to leave a comment

TODAY ON YAHOO!

Business

A construction worker attaches shutters to a new home in Bristow, Virginia in September. US new home sales rebounded more than expected in October to their strongest pace in more than a year, government data showed, suggesting stabilization in the ailing sector.  Photo:Paul J. Richards/AFP


US new home sales rebound in October
AFP - WASHINGTON (AFP) - US new home sales rebounded more than expected in October to their...

Sports

Soccer-CSKA Moscow v VfL Wolfsburg - teams
Reuters - MOSCOW, Nov 25 (Reuters) - Teams for Wednesday's Champions League Group B match between...

Top stories

Nick Reilly, interim head of General Motor's European business speaks during a news conference at the headquarters of German carmaker Opel in Ruesselsheim on November 25, 2009. REUTERS/Ralph Orlowski (GERMANY - Tags: BUSINESS EMPLOYMENT TRANSPORT)


Threat of GM plant closures cast doubts on future
The Canadian Press - RUESSELSHEIM, Germany - General Motors' top European official said Wednesday...